pseries

AIX – DLPAR connection lost to HMC

Sometime during AIX migration/alt_clone or HMC upgrade, it can happen that RMC ID get lost or duplicated, the the rsct process is unable to re stabilize the connection.

You can reset the key and restart that service as follows:

Reset RMC unique ID:

# /usr/sbin/rsct/install/bin/recfgct
# /usr/sbin/rsct/bin/rmcctrl -z
# /usr/sbin/rsct/bin/rmcctrl -A


Then you can check the rmc status:

# /usr/sbin/rsct/bin/rmcdomainstatus -s ctrmc

AIX – DLPAR connection lost to HMC Read More »

pSeries – 10117611 U0.1-F1

I’m getting this error on a 9114-275.

SYSTEM POWER CONTROL MENU

1. Enable/Disable Unattended Start Mode:
Currently Enabled

2. Ring Indicate Power-On Menu
3. Reboot/Restart Policy Setup Menu
4. Power-On System
5. Power-Off System
6. Enable/Disable Fast System Boot:
Currently Slow Boot

7. Boot Mode Menu
98. Return to Previous Menu
99. Exit from Menus

After digits “4”

Please wait....

System Powering On. Exiting menus.
9022
9101
90FD
10117611 U0.1-F1
B0FF
OK x

The error on planar was located on FAN module, for resolution unplug entire block and single fans, then replug into the planar after cleaning up, then power on your pSeries.

pSeries – 10117611 U0.1-F1 Read More »